旭化成 南亚 东丽 巴斯夫 罗地亚 普立万 长春

杜邦 泰科纳 三菱工程 GE料 朗盛 RTP 舒尔曼

改性尼龙 改性PBT 代理PTFE聚四氟乙烯粉

塑料种类

通用塑料 PVCGPPSHDPELDPEHIPSSAN

工程塑料 PVDFPSUPPSUPOPPFAPA4TPA9TPA6TPA610PA1010PA12PA11EPSEMAPPOCOCPA46PA6PA6/66PA612PEEKPPEPTFE

热塑弹性体CPETPVSISSBSSBRPBEPOETPX

联系我们

塑胶原料报价
PPO HS1000X 矿物13%增强,无溴氯阻燃,尺寸稳定
  • 产 品:PPO HS1000X 矿物13%增强,无溴氯阻燃,尺寸稳定
  • 产 地:沙伯基础创新
  • 价 格:电话报价
  • 库 存:20吨
  • 交 货:江苏苏州
  • 苏州希普能:185 5121 3137 谭经理

Noryl* FR Reinforced Resin
Flame Retardant, Heat Resistant
General purpose, reinforced modified amorphous blends of PPO* resin (polyphenylene ether) and polystyrene or high-impact polystyrene with non-brominated, non-chlorinated flame retardants.

Noryl* Resin HS1000X 英文物性表
PPE+PS blend. 13% Mineral reinforced. Non-brominated, non-chlorinated FR system. UL94 V0 and 5VA listing. UL 746C f1. Radiant Panel listing. Dielectric strength. Dimensional stability. Suitable for E/E applications.

Property
TYPICAL PROPERTIES (1)

MECHANICAL Value Unit  Standard 
Tensile Stress,yld,Type I,5mm/min 660 kgf/cm² ASTM D 638
Tensile Stress,brk,Type I,5mm/min 520 kgf/cm² ASTM D 638
Tensile Strain,yld,Type I,5mm/min 7.6 % ASTM D 638
Tensile Strain,brk,Type I,5mm/min 30 % ASTM D 638
Flexural Stress,yld,2.6mm/min,100mm span 1050 kgf/cm² ASTM D 790
Flexural Modulus,2.6mm/min,100mm span 29500 kgf/cm² ASTM D 790
Hardness,Rockwell R 121 - ASTM D 785
IMPACT Value Unit  Standard 
Izod Impact,unnotched,23℃ 154 cm-kgf/cm ASTM D 4812
Izod Impact,notched,23℃ 13 cm-kgf/cm ASTM D 256
Instrumented Impact Energy @ peak,23℃ 254 cm-kgf ASTM D 3763
THERMAL Value Unit  Standard 
Vicat Softening Temp,Rate B/50 125 ASTM D 1525
HDT,0.45 MPa,6.4mm,unannealed 98 ASTM D 648
HDT,1.82 MPa,6.4mm,unannealed 93 ASTM D 648
Relative Temp Index,Elec 100 UL 746B
Relative Temp Index,Mech w/impact 85 UL 746B
Relative Temp Index,Mech w/o impact 100 UL 746B
PHYSICAL Value Unit  Standard 
Specific Gravity 1.23 - ASTM D 792
Water Absorption,24 hours 0.07 % ASTM D 570
Mold Shrinkage,flow,3.2mm (5) 0.5-0.7 % SABIC Method
ELECTRICAL Value Unit  Standard 
Volume Resistivity 1.60E+16 Ohm-cm ASTM D 257
Surface Resistivity >1.E+16 Ohm ASTM D 257
Dielectric Strength,inoil,3.2mm 17.7 kV/mm ASTM D 149
Relative Permittivity,50/60 Hz 3.03 - ASTM D 150
Relative Permittivity,1 MHz 2.83 - ASTM D 150
Dissipation Factor,50/60 Hz 0.027 - ASTM D 150
Dissipation Factor,1 MHz 0.007 - ASTM D 150
Arc Resistance,Tungsten {PLC} 6 PLC Code ASTM D 495
Hot Wire Ignition {PLC) 0 PLC Code UL 746A
High Voltage Arc Track Rate {PLC} 2 PLC Code UL 746A
High Ampere Arc Ign,surface {PLC} 4 PLC Code UL 746A
Comparative Tracking Index (UL) {PLC} 2 PLC Code UL 746A
FLAME CHARACTERISTICS Value Unit  Standard 
UL Recognized,94V-0 Flame Class Rating (3) 1.01 mm UL 94
UL Recognized,94-5VA Rating (3) 2.48 mm UL 94
Radiant Panel Listing YES - UL Tested
UV-light,water exposure/immersion F1 - UL 746C
Source GMD,last updated:1999/12/29
Parameter Injection Molding Value Unit 
Drying Temperature 90-95
Drying Time 3-4 hrs
Drying Time (Cumulative) 8 hrs
Maximum Moisture Content 0.02 %
Melt Temperature 255-280
Nozzle Temperature 255-280
Front-Zone 3 Temperature 245-280
Middle-Zone 2 Temperature 230-275
Rear-Zone 1 Temperature 220-270
Mold Temperature 65-90
Back Pressure 0.3-0.7 MPa
Screw Speed 20-100 rpm
Shot to Cylinder Size 30-70 %
Vent Depth 0.038-0.051 mm
Source GMD,last updated:1999/12/29

THESE PROPERTY VALUES ARE NOT INTENDED FOR SPECIFICATION PURPOSES.
PLEASE CONTACT US FOR AVAILABILITY IN YOUR REGION.
1、Typical values only. Variations within normal tolerances are possible for various colors. All values are measured after at least 48 hours storage at 23℃/50% relative humidity. All properties, except the melt volume and melt flow rates, are measured on injection molded samples. All samples tested under ISO test standards are prepared according to ISO 294.
2、 Only typical data for selection purposes. Not to be used for part or tool design.
3、This rating is not intended to reflect hazards presented by this or any other material under actual fire conditions.
4、Internal measurements according to UL standards.
5、Measurements made from laboratory test coupon. Actual shrinkage may vary outside of range due to differences in processing conditions, equipment, part geometry and tool design. It is recommended that mold shrinkage studies be performed with surrogate or legacy tooling prior to cutting tools for new molded article.

链接:TPU-TPE材料