旭化成 南亚 东丽 巴斯夫 罗地亚 普立万 长春

杜邦 泰科纳 三菱工程 GE料 朗盛 RTP 舒尔曼

改性尼龙 改性PBT 代理PTFE聚四氟乙烯粉

塑料种类

通用塑料 PVCGPPSHDPELDPEHIPSSAN

工程塑料 PVDFPSUPPSUPOPPFAPA4TPA9TPA6TPA610PA1010PA12PA11EPSEMAPPOCOCPA46PA6PA6/66PA612PEEKPPEPTFE

热塑弹性体CPETPVSISSBSSBRPBEPOETPX

联系我们

塑胶原料报价
PC OQ1022 易脱模,热稳定,透明,光盘应用
  • 产 品:PC OQ1022 易脱模,热稳定,透明,光盘应用
  • 产 地:沙伯基础创新
  • 价 格:电话报价
  • 库 存:20吨
  • 交 货:江苏苏州
  • 苏州希普能:185 5121 3137 谭经理

Lexan* Media Resin
Resin for CD-ROM & DVD
Optical Quality resins provide the pure quality needed for Optical Media applications. Different grades are available for CD, DVD, recordable and re-writable formats.

Lexan* Resin OQ1022 英文数据物性表
Standard Flow OQ Resin

Property
TYPICAL PROPERTIES (1)

MECHANICAL Value Unit  Standard 
Tensile Stress,yld,Type I,50 mm/min 620 kgf/cm² ASTM D 638
Tensile Stress,brk,Type I,50 mm/min 520 kgf/cm² ASTM D 638
Tensile Strain,yld,Type I,50 mm/min 6 % ASTM D 638
Tensile Strain,brk,Type I,50 mm/min 100 % ASTM D 638
Tensile Modulus,50 mm/min 24600 kgf/cm² ASTM D 638
Flexural Stress,brk,1.3 mm/min,50 mm span 940 kgf/cm² ASTM D 790
Flexural Modulus,1.3 mm/min,50 mm span 25000 kgf/cm² ASTM D 790
Tensile Stress,yield,50 mm/min 61 MPa ISO 527
Tensile Stress,break,50 mm/min 56 MPa ISO 527
Tensile Strain,yield,50 mm/min 5.9 % ISO 527
Tensile Strain,break,50 mm/min 108 % ISO 527
Tensile Modulus,1 mm/min 2440 MPa ISO 527
Flexural Stress,yield,2 mm/min 90 MPa ISO 178
Flexural Modulus,2 mm/min 2400 MPa ISO 178
IMPACT Value Unit  Standard 
Izod Impact,notched,23℃ 56 cm-kgf/cm ASTM D 256
Izod Impact,notched,-30℃ NB cm-kgf/cm ASTM D 256
Instrumented Impact Total Energy,23℃ 469 cm-kgf ASTM D 3763
Izod Impact,unnotched 80*10*3 +23℃ NB kJ/m² ISO 180/1U
Izod Impact,unnotched 80*10*3 -30℃ NB kJ/m² ISO 180/1U
Izod Impact,notched 80*10*3 +23℃ 14 kJ/m² ISO 180/1A
Izod Impact,notched 80*10*3 -30℃ 11 kJ/m² ISO 180/1A
Charpy 23℃,V-notch Edgew 80*10*3 sp=62mm 40 kJ/m² ISO 179/1eA
Charpy -30℃,V-notch Edgew 80*10*3 sp=62mm 11 kJ/m² ISO 179/1eA
Charpy 23℃,Unnotch Edgew 80*10*3 sp=62mm NB kJ/m² ISO 179/1eU
Charpy -30℃,Unnotch Edgew 80*10*3 sp=62mm NB kJ/m² ISO 179/1eU
THERMAL Value Unit  Standard 
Vicat Softening Temp,Rate B/50 140 ASTM D 1525
HDT,1.82 MPa,3.2mm,unannealed 123 ASTM D 648
CTE,-40℃ to 40℃,flow 8.10E-05 1/℃ ASTM E 831
CTE,-40℃ to 40℃,xflow 7.20E-05 1/℃ ASTM E 831
CTE,23℃ to 80℃,flow 7.00E-05 1/℃ ISO 11359-2
CTE,23℃ to 80℃,xflow 7.00E-05 1/℃ ISO 11359-2
Ball Pressure Test,75℃ +/- 2℃ NB - IEC 60695-10-2
Vicat Softening Temp,Rate B/50 140 ISO 306
Vicat Softening Temp,Rate B/120 141 ISO 306
HDT/Ae, 1.8 MPa Edgew 120*10*4 sp=100mm 121 ISO 75/Ae
PHYSICAL Value Unit  Standard 
Specific Gravity 1.19 - ASTM D 792
Mold Shrinkage, flow, 3.2 mm (5) 0.6 - 0.8 % SABIC Method
Mold Shrinkage, xflow, 3.2 mm (5) -0.1 % SABIC Method
Melt Flow Rate, 250℃/1.2 kgf 11 g/10 min ASTM D 1238
Density 1.19 g/cm³ ISO 1183
Water Absorption, (23℃/sat) 0.2 % ISO 62
Moisture Absorption (23℃ / 50% RH) 0.2 % ISO 62
Melt Volume Rate, MVR at 250℃/1.2 kg 10 cm³/10 min ISO 1133
Source GMD, last updated:2004/06/02
Parameter Injection Molding Value Unit 
Drying Temperature 120
Drying Time 3-4 hrs
Drying Time (Cumulative) 48 hrs
Maximum Moisture Content 0.02 %
Melt Temperature 305-330
Nozzle Temperature 305-330
Front-Zone 3 Temperature 305-330
Middle-Zone 2 Temperature 295-320
Rear-Zone 1 Temperature 280-310
Mold Temperature 65-95
Back Pressure 0.3-0.7 MPa
Screw Speed 60-200 rpm
Source GMD,last updated:2004/06/02

THESE PROPERTY VALUES ARE NOT INTENDED FOR SPECIFICATION PURPOSES.
PLEASE CONTACT US FOR AVAILABILITY IN YOUR REGION.

1、Typical values only. Variations within normal tolerances are possible for various colors. All values are measured after at least 48 hours storage at 23℃/50% relative humidity. All properties, except the melt volume and melt flow rates, are measured on injection molded samples. All samples tested under ISO test standards are prepared according to ISO 294.
2、Only typical data for selection purposes. Not to be used for part or tool design.
3、This rating is not intended to reflect hazards presented by this or any other material under actual fire conditions.
4、Internal measurements according to UL standards.
5、Measurements made from laboratory test coupon. Actual shrinkage may vary outside of range due to differences in processing conditions, equipment, part geometry and tool design. It is recommended that mold shrinkage studies be performed with surrogate or legacy tooling prior to cutting tools for new molded article.
代理沙伯基础创新塑料(PC)聚碳酸酯材料:http://www.pa66-suliao.com/product/gcsuliao/PEEK/