旭化成 南亚 东丽 巴斯夫 罗地亚 普立万 长春

杜邦 泰科纳 三菱工程 GE料 朗盛 RTP 舒尔曼

改性尼龙 改性PBT 代理PTFE聚四氟乙烯粉

塑料种类

通用塑料 PVCGPPSHDPELDPEHIPSSAN

工程塑料 PVDFPSUPPSUPOPPFAPA4TPA9TPA6TPA610PA1010PA12PA11EPSEMAPPOCOCPA46PA6PA6/66PA612PEEKPPEPTFE

热塑弹性体CPETPVSISSBSSBRPBEPOETPX

联系我们

塑胶原料报价
PA6 PX08322 导热矿物填充阻燃尼龙6
  • 产 品:PA6 PX08322 导热矿物填充阻燃尼龙6
  • 产 地:美国液氮
  • 价 格:电话报价
  • 库 存:20吨
  • 交 货:江苏苏州
  • 苏州希普能:185 5121 3137 谭经理

LNP* Konduit* Compound
LNP Konduit Resin All Series
LNP* Konduit* composite compounds are 10 to 50 times more thermally conductive than conventional unfilled thermoplastics. Konduit composite compounds can conduct heat away from devices into a heat sink or the surrounding air. LNP* specialty compound offerings are available in a broad portfolio of standard and engineering materials

LNP™ Konduit™ Compound PA6 PX08322 塑料物性

Also known as:LNP™Konduit™Compound PX08322
Product reorder name:PX08322
Thermally conductive mineral filled PA6 FR compound, with through-plane and in-plane thermal conductivity of 2.1 W/(m*K) and 8.1 W/(m*K) respectively, conforming to ASTM E 1461 test standard.

MECHANICAL Value Unit Standard
Tensile Stress,brk,Type I,5mm/min 550 kgf/cm² ASTM D 638
Tensile Strain,brk,Type I,5mm/min 0.6 % ASTM D 638
Tensile Modulus,50mm/min 120300 kgf/cm² ASTM D 638
Flexural Stress,brk,1.3mm/min,50mm span 830 kgf/cm² ASTM D 790
Flexural Modulus,1.3mm/min,50mm span 119300 kgf/cm² ASTM D 790
IMPACT Value Unit Standard
Izod Impact,unnotched,23℃ 8 cm-kgf/cm ASTM D 4812
Izod Impact,notched,23℃ 1 cm-kgf/cm ASTM D 256
THERMAL Value Unit Standard
HDT,1.82 MPa,6.4mm,unannealed 180 ASTM D 648
CTE,-40℃ to 40℃,flow 2.15E-05 1/℃ ASTM E 831
CTE,-40℃ to 40℃,xflow 3.54E-05 1/℃ ASTM E 831
CTE,40℃ to 120℃,flow 2.71E-05 1/℃ ASTM E 831
CTE,40℃ to 120℃,xflow 5.83E-05 1/℃ ASTM E 831
Specific Heat 1.39 J/g-℃ ASTM C 351
Thermal Conductivity 2.3 W/m-℃ ASTM E 1530
Ball Pressure Test,125℃ +/- 2℃ 0 - IEC 60695-10-2
PHYSICAL Value Unit Standard
Density 1.52 g/cm³ ASTM D 792
Mold Shrinkage,flow,24 hrs(5) 0.5 % ASTM D 955
Mold Shrinkage,xflow,24 hrs(5) 0.45 % ASTM D 955
Melt Flow Rate,285ºC/6.7 kgf 15.3 g/10 min ASTM D 1238
Water Absorption,23℃/24hrs 0.39 % SABIC Method
Moisture Absorption(23℃ / 50% RH) 0.06 % ISO 62
ELECTRICAL Value Unit Standard
Surface Resistivity >1.E+15 Ohm ASTM D 257
Dielectric Strength,in oil,1.0mm 14.1 kV/mm ASTM D 149
Relative Permittivity,50/60 Hz 7.27 - ASTM D 150
Relative Permittivity,1 MHz 4.8 - ASTM D 150
Dissipation Factor,50/60 Hz 0.083 - ASTM D 150
Dissipation Factor,1 MHz 0.043 - ASTM D 150
Hot Wire Ignition{PLC) 0 PLC Code UL 746A
High Ampere Arc Ign,surface{PLC} 0 PLC Code UL 746A
Comparative Tracking Index 575 V IEC 60112
FLAME CHARACTERISTICS Value Unit Standard
UL Recognized,94V-0 Flame Class Rating(3) 1.2 mm UL 94
Glow Wire Ignitability Temperature,1.0mm 825 IEC 60695-2-13
Source GMD,last updated:2011/05/09
Parameter Injection Molding Value Unit
Drying Temperature 80-90
Drying Time 3-4 hrs
Maximum Moisture Content 0.01 %
Melt Temperature 250-280
Nozzle Temperature 250-280
Front-Zone 3 Temperature 250-280
Middle-Zone 2 Temperature 240-280
Rear-Zone 1 Temperature 230-270
Mold Temperature 80-100
Back Pressure 3-9 MPa
Screw Speed 30-150 rpm
Source GMD,last updated:2011/05/09

THESE PROPERTY VALUES ARE NOT INTENDED FOR SPECIFICATION PURPOSES.
 Buy SABIC Innovative please contact xiang zhang Engineering plastics

1、Typical values only. Variations within normal tolerances are possible for various colors. All values are measured after at least 48 hours storage at 23℃/50% relative humidity. All properties, except the melt volume and melt flow rates, are measured on injection molded samples. All samples tested under ISO test standards are prepared according to ISO 294.
2、Only typical data for selection purposes. Not to be used for part or tool design.
3、This rating is not intended to reflect hazards presented by this or any other material under actual fire conditions.
4、Internal measurements according to UL standards.
5、Measurements made from laboratory test coupon. Actual shrinkage may vary outside of range due to differences in processing conditions, equipment, part geometry and tool design. It is recommended that mold shrinkage studies be performed with surrogate or legacy tooling prior to cutting tools for new molded article.m-PPE EHM1000 9905M 炭纤充填,导电级

关健字:【LNP™ Konduit™ Compound PA6 PX08322