旭化成 南亚 东丽 巴斯夫 罗地亚 普立万 长春

杜邦 泰科纳 三菱工程 GE料 朗盛 RTP 舒尔曼

改性尼龙 改性PBT 代理PTFE聚四氟乙烯粉

塑料种类

通用塑料 PVCGPPSHDPELDPEHIPSSAN

工程塑料 PVDFPSUPPSUPOPPFAPA4TPA9TPA6TPA610PA1010PA12PA11EPSEMAPPOCOCPA46PA6PA6/66PA612PEEKPPEPTFE

热塑弹性体CPETPVSISSBSSBRPBEPOETPX

联系我们

塑胶原料报价
PA12 SX93441D 专有填料复合尼龙12,内部润滑
  • 产 品:PA12 SX93441D 专有填料复合尼龙12,内部润滑
  • 产 地:美国液氮
  • 价 格:电话报价
  • 库 存:20吨
  • 交 货:江苏苏州
  • 苏州希普能:185 5121 3137 谭经理

NP* Lubricomp* Compound
LNP Lubricomp Resin All Series
LNP* Lubricomp* compounds provide improved wear resistance and lower friction by combining engineering resins with internal lubricants. Lubricomp compounds, which can also be stiffened with glass or other fiber, can help extend product life and reduce or eliminate squeaks and other noise from moving parts. LNP specialty compound offerings are available in a broad portfolio of standard and engineering materials.

LNP™ LUBRICOMP™ Compound PA12 SX93441D 塑料数据

Also known as:LNP™ Lubricomp™ Compound PDX-S-93441
Product reorder name:SX93441D
LNP* Lubricomp* SX93441D is a compound based on Nylon 12 containing Proprietary Fillers. Characteristics of this grade are: Internally Lubricated.

MECHANICAL Value Unit Standard
Tensile Stress,yld,Type I,5mm/min 940 kgf/cm² ASTM D 638
Tensile Stress,brk,Type I,5mm/min 870 kgf/cm² ASTM D 638
Tensile Strain,yld,Type I,5mm/min 4.9 % ASTM D 638
Tensile Strain,brk,Type I,5mm/min 6.1 % ASTM D 638
Tensile Modulus,50mm/min 55100 kgf/cm² ASTM D 638
Flexural Modulus,1.3mm/min,50mm span 45600 kgf/cm² ASTM D 790
Tensile Stress,yield,5mm/min 92 MPa ISO 527
Tensile Stress,break,5mm/min 91 MPa ISO 527
Tensile Strain,yield,5mm/min 4.9 % ISO 527
Tensile Strain,break,5mm/min 6.3 % ISO 527
Tensile Modulus,1mm/min 5410 MPa ISO 527
Flexural Stress 136 MPa ISO 178
Flexural Modulus,2mm/min 4720 MPa ISO 178
IMPACT Value Unit Standard
Izod Impact,unnotched,23℃ 88 cm-kgf/cm ASTM D 4812
Izod Impact,notched,23℃ 12 cm-kgf/cm ASTM D 256
Multiaxial Impact 37 cm-kgf ISO 6603
Instrumented Impact Total Energy,23℃ 163 cm-kgf ASTM D 3763
Izod Impact,unnotched 80*10*4 +23℃ 58 kJ/m² ISO 180/1U
Izod Impact,notched 80*10*4 +23℃ 10 kJ/m² ISO 180/1A
THERMAL Value Unit Standard
HDT,0.45 MPa,3.2mm,unannealed 175 ASTM D 648
HDT,1.82 MPa,3.2mm,unannealed 161 ASTM D 648
CTE,-30℃ to 30℃,flow 4.00E+01 1/℃ ASTM D 696
CTE,-30℃ to 30℃,xflow 1.35E+03 1/℃ ASTM D 696
HDT/Bf,0.45 MPa Flatw 80*10*4 sp=64mm 170 ISO 75/Bf
HDT/Af,1.8 MPa Flatw 80*10*4 sp=64mm 146 ISO 75/Af
PHYSICAL Value Unit Standard
Specific Gravity 1.2 - ASTM D 792
Density 1.19 g/cm³ ASTM D 792
Moisture Absorption,50% RH,24 hrs 0.15 % ASTM D 570
Mold Shrinkage,flow,24 hrs(5) 0.3-0.6 % ASTM D 955
Mold Shrinkage,xflow,24 hrs(5) 0.9-2 % ASTM D 955
Wear Factor Washer 51 10^-10 in^5-min/ft-lb-hr ASTM D 3702 Modified
Wear Factor Ring 7 10^-10 in^5-min/ft-lb-hr ASTM D 3702 Modified
Dynamic COF 0.48 - ASTM D 3702 Modified
Static COF 0.47 - ASTM D 3702 Modified
Moisture Absorption(23℃/50% RH) 0.2 % ISO 62
Source GMD,last updated:2011/04/11
Parameter Injection Molding Value Unit
Drying Temperature 80
Drying Time 4 hrs
Maximum Moisture Content 0.12-0.2 %
Melt Temperature 225-240
Front-Zone 3 Temperature 225-240
Middle-Zone 2 Temperature 220-230
Rear-Zone 1 Temperature 215-225
Mold Temperature 70-80
Back Pressure 0.2-0.3 MPa
Screw Speed 30-60 rpm
Source GMD,last updated:2011/04/11

THESE PROPERTY VALUES ARE NOT INTENDED FOR SPECIFICATION PURPOSES.
Buy SABIC Innovative please contact xiang zhang Engineering plastics

1、Typical values only. Variations within normal tolerances are possible for various colors. All values are measured after at least 48 hours storage at 23℃/50% relative humidity. All properties, except the melt volume and melt flow rates, are measured on injection molded samples. All samples tested under ISO test standards are prepared according to ISO 294.
2、Only typical data for selection purposes. Not to be used for part or tool design.
3、This rating is not intended to reflect hazards presented by this or any other material under actual fire conditions.
4、Internal measurements according to UL standards.
5、Measurements made from laboratory test coupon. Actual shrinkage may vary outside of range due to differences in processing conditions, equipment, part geometry and tool design. It is recommended that mold shrinkage studies be performed with surrogate or legacy tooling prior to cutting tools for new molded article.

关健字:【LNP™ LUBRICOMP™ Compound PA12 SX93441D