VECTRA® MT® 4310 VF3001 NATURAL

VECTRA MT4310 | LCP | Medical Technology

Description
Highest temperature capability, easiest flow. Suitable where very thin walls are required. Used for broad range of SMT applications, with minimal dimensional change. 30% glass filled.

Chemical abbreviation according to ISO 1043-1 : LCP
Inherently flame retardant

Ticona has established at the FDA a drug master file (DMF no.8468) and a Device Master File (MAF no.315) for Vectra MT4310. These are to assist our customers with their end use FDA petitions. Vectra MT4310 has been tested and complies with USP Class VI.

Other Processing
Injection Molding
A three-zone screw evenly divided into feed, compression, and metering zones is preferred. A higher percentage of feed flights may be needed for smaller machines: 1/2 feed, 1/4 compression, 1/4 metering.

Vectra LCPs are shear thinning, their melt viscosity decreases quickly as shear rate increases. For parts that are difficult to fill, the molder can increase the injection velocity to improve melt flow.

ISO Data Physical properties Value Unit Test Standard
Phys Density 1610 kg/m³ ISO 1183
Mold shrinkage - parallel 0.1 % ISO 294-4
Mold shrinkage - normal 0.5 % ISO 294-4
Mech Mechanical properties Value Unit Test Standard
Tensile modulus (1mm/min) 15000 MPa ISO 527-2/1A
Tensile stress at break (5mm/min) 150 MPa ISO 527-2/1A
Tensile strain at break (5mm/min) 1.6 % ISO 527-2/1A
Flexural modulus (23℃) 15000 MPa ISO 178
Flexural strength (23℃) 225 MPa ISO 178
Compressive stress @ 1% strain 93 MPa ISO 604
Charpy impact strength @ 23℃ 43 kJ/m² ISO 179/1eU
Charpy notched impact strength @ 23℃ 22 kJ/m² ISO 179/1eA
Unnotched impact str (Izod) @ 23℃ 31 kJ/m² ISO 180/1U
Notched impact strength (Izod) @ 23℃ 20 kJ/m² ISO 180/1A
Compressive modulus 14000 MPa ISO 604
Rockwell hardness 71 M-Scale ISO 2039-2
Therm Thermal properties Value Unit Test Standard
Melting temperature (10℃/min) 335 ISO 11357-1,-2,-3
DTUL @ 1.8 MPa 276 ISO 75-1/-2
DTUL @ 8.0 MPa 216 ISO 75-1/-2
Vicat softening temperature B50 (50℃/h 50N) 195 ISO 306
Coeff.of linear therm. expansion (parallel) 0.07 E-4/℃ ISO 11359-2
Coeff.of linear therm. expansion (normal) 0.2 E-4/℃ ISO 11359-2
Limiting oxygen index (LOI) 45 % ISO 4589
Flammability at thickness h V-0 class UL94
Elec Electrical properties Value Unit Test Standard
Relative permittivity - 100 Hz 4 - IEC 60250
Relative permittivity - 1 MHz 3.3 - IEC 60250
Dissipation factor - 100 Hz 100 E-4 IEC 60250
Dissipation factor - 1 MHz 250 E-4 IEC 60250
Volume resistivity 1.00E+13 Ohm*m IEC 60093
Surface resistivity 1.00E+14 Ohm IEC 60093
Electric strength 32 kV/mm IEC 60243-1
Comparative tracking index CTI 200 - IEC 60112
Arc resistance 140 s Internal
SpecProd Test specimen production Value Unit Test Standard
Injection molding melt temperature 340 ISO 294
Injection molding mold temperature 100 ISO 294
Injection molding flow front velocity 150 mm/s ISO 294
Injection molding hold pressure 69 MPa ISO 294

Processing
Pre Drying
Necessary low maximum residual moisture content: 0.01%

VECTRA should in principle be predried. Because of the necessary low maximum residual moisture content the use of dry air dryers is recommended. The dew point should be =< - 40℃. The time between drying and processing should be as short as possible.

For subsequent storage of the material in the dryer until processed the temperature does not need to be lowered for grades A, B, C, D and V (<= 24 h).

Drying time (h):4-6
Drying temperature (℃):150-150